產品中心

大鼠調節激活正常T-細胞表達分泌因子(RANTES)微量上樣酶聯免疫吸附檢測試劑盒
一鍵復制產品信息
ELK10229MS
規格: 價格:
48T ¥1680.00
96T ¥2400.00
96T*5 ¥10200.00

Overview

Product name: Rat RANTES(Regulated On Activation In Normal T-Cell Expressed And Secreted) Microsample ELISA Kit
Reactivity: Rat
Alternative Names: CCL5; SCYA5; SISd; EoCP; Chemokine C-C-Motif Ligand 5; Eosinophil Chemotactic Cytokine; T-cell Specific Protein p288; Small Inducible Cytokine Subfamily A(Cys-Cys)Member 5
Assay Type: Sandwich
Sensitivity: 0.101 ng/mL
Standard: 20 ng/mL
Detection Range: 0.32-20 ng/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Cytokine;Tumor immunity;Infection immunity;Immune molecule;
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Rat RANTES. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Rat RANTES. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Rat RANTES, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Rat RANTES in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (ng/mL) OD Corrected OD
20.00 2.242 2.148
10.00 1.720 1.626
5.00 1.062 0.968
2.50 0.676 0.582
1.25 0.445 0.351
0.63 0.297 0.203
0.31 0.197 0.103
0.00 0.094 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant RANTES and the recovery rates were calculated by comparing the measured value to the expected amount of RANTES in samples.
Matrix Recovery range Average
serum(n=5) 91-99% 95%
EDTA plasma(n=5) 81-97% 89%
Heparin plasma(n=5) 89-94% 92%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of RANTES and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 91-105% 92-104% 87-95% 92-119%
EDTA plasma(n=5) 88-93% 84-117% 82-87% 80-118%
Heparin plasma(n=5) 87-102% 92-101% 91-112% 94-112%